名称描述内容
    
​           科研成果

部分国际论文


Leiming Gao, Zikai Hua, Robert Hewson. Can a “pre-worn” bearing surface geometry reduce the wear of metal-on-metal hip replacements? – A numerical wear simulation study, Wear, 406–407 (2018) 13–21.


Bian Yan-Yan;Zhou Lei;Zhou Gang;Jin Zhong-Min;Xin Shi-Xuan;Hua Zi-Kai;Weng Xi-Sheng,Study on biocompatibility, tribological property and wear debris characterization of ultra-low-wear polyethylene as artificial joint materials,JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS,82, 87-94:2017.


Jia-Ming Liu, Yu Zhang, Yang Zhou, Xuan-Yin Chen, Shan-Hu Huang, Zi-Kai Hua, Zhi-Li Liu, The effect of screw tunnels on the biomechanical stability of vertebral body after pedicle screws removal: a finite element analysis, International Orthopaedics (SICOT), 2017, June, Volume 41, Issue 6, pp 1183–1187, DOI: 10.1007/s00264-017-3453-y, IF:2.520, Q1, WOS:000402135800016.


Chun-Lin Zhang, Guo-Qi Shen, Kun-Peng Zhu, Dong-xu Liu, Biomechanical effects of morphological variations of the cortical wall at the bone-cement interface, Journal of Orthopaedic Surgery and Research (2016) 11:72, DOI 10.1186/s13018-016-0405-y,  IF: 2.387.


张立峰,张元智,华子恺,莫伟鹏,贾燕飞,髋臼前柱顺行拉力螺钉固定钉道的设计及有限元分析,中华骨科杂志, 2017, 37(5)2016


Dongxu Liu, Zikai Hua*, Xinyi Yan, Zhongmin Jin, Design and biomechanical study of a novel adjustable hemipelvic prosthesis, Medical Engineering and Physics, 2016, Volume 38, Issue 12, December 2016, Pages 1416–1425. IF: 1.819, WOS:000389395900005,Q3.


Dongxu Liu, Zikai Hua*, Xinyi Yan, Zhongmin Jin, Biomechanical analysis of a novel hemipelvic endoprosthesis during ascending and descending stairs, Proc IMechE Part H 2016, 230(10): 962-975. IF: 0.809, WOS:000386795100006, Q3.


Dongxu Liu,  Jianfeng Jiang, , Lei Wang, Jie Liu,  Zhongmin Jin, Leiming Gao, Zhengdong Cai,Yingqi Hua, Zikai Hua, In vitro experimental and numerical study on biomechanics and stability of a novel adjustable hemipelvic prosthesis, Journal of the Mechanical Behavior of Biomedical Materials 90 (2019) 626–634.


Z.K. Hua, X.Y. Yan, D.X. Liu, Z.M. Jin, X.J. Wang, L.L. Liu, Analysis of the friction induced squeaking of ceramic-on-ceramic hip prostheses using a pelvic bone finite element model, Tribology Letters, 2016, 61(26):1-7. 


Z.K. Hua, X.Y. Yan, D.X. Liu, Z.M. Jin, X.J. Wang, L.L. Liu, Analysis of the friction induced squeaking of ceramic-on-ceramic hip prostheses using a pelvic bone finite element model, Tribology Letters, 2016, 61(26):1-7.


Z.K. Hua, F.Tang, H.Y. Bai,A Titanium Dioxide Nano Film Encapsulation for Metal Orthopedic Implants in Diathermy Rehabilitation Therapy, Nanoscience and Nanotechnology Letters, Vol.7, No.3, 268-271.


LIU Dong-xu, YAN Xin-yi, HUA Zi-kai. Biomechanical study of the type I+II+III standard hemipelvic prosthesis in the single-leg stance (in Chinese). Journal of Medical Biomechanics, 2015, 30(6):31-37.


Z.K. Hua, Y.W. Fan, Z.M. Jin, A biotribo-acoustic testing method for ceramic orthopaedic biomaterials, Tribology International, Vol. 71, 1-6, 2014.


Z.K. Hua, H.H. Zhang, Y.W. Fan, Z.M. Jin, Development of a BiotriboPOD testing methodology for the wear evaluation of orthopaedic biomaterials, RSC Adv., 2014, 4 (38), 19987 – 19991.


Z.K. Hua, Y.W. Fan, A new Ortho-POD Biotribometer for Orthopaedic Biomaterials wear testing, Applied Mechanics and Materials, Vol. 461 (2014) pp 367-372.


Z.K. Hua, Y.W. Fan, Q.H. Cao, X.B. Wu, Biomechanical study on the novel biomimetic hemi-pelvis prosthesis, Journal of Bionic Engineering, Vol. 10, Issue 4, 506-513, 2013.


Z.K. Hua, G. Mcknight, J. McCloy, Study on Tribological and Electrochemical Performance of Metal Artificial Hip Joint Materials in Simulated Synovial Fluids, ASTM Special Technical Publication, v 1560 STP, p 323-331, 2013.


Z.K. Hua, R. Z. Sang,Micro and Nano-Scale Surface Texturing: An Application in Ceramic-on-Ceramic Artificial Joint Materials. Nanoscience and Nanotechnology Letters, Vol. 4, 879–882, 2012.


Z.K. Hua, Tribological Study on the Bionic Therapeutic Fluids. Tribology Letters ,Oct 2007, 28(1):51-58.


Z.K. Hua, A new simulator for bio-tribological study, Journal of Bionic Engineering, Sept 2008, Vol.5 Suppl., pp.143-147.


Hua Zikai,Tribological and electrochemical studies on biomimetic synovial fluids, Sci China Ser E-Tech Sci, 2010, Vol.53, No.11, pp. 2996-3001.

微信平台

小关节